AK-17024-SCH-06

Non-Destructive Testing (NDT) Level II Technician (UT / MT / PT)

Governed under ISO 9712:2021, ASNT SNT-TC-1A, and EN ISO 17635 for ultrasonic, magnetic particle, and liquid penetrant inspection.

StandardISO 9712 / ASNT
Credential Validity3 Years (Annual Vision)
Assessment FeeAED 1,800 / Candidate
Lead ExaminersJuliya Nishad / Ubayathulla I
General & Specific Examination

A 120-minute examination comprising General Theory (40 MCQs) and Specific Code Method (30 MCQs). Passing mark is 80% on each section.

  • Ultrasonic wave physics & velocity calibration blocks
  • Magnetic particle flux leakage and yoke field strength
  • Penetrant dwell time, developer wash, and UV lighting
  • ASME Section V and Section VIII acceptance limits
Practical Specimen Defect Sizing

A 180-minute hands-on assessment inspecting welded plates and pipes with introduced blind discontinuities. Passing score is 80%+.

  • Instrument calibration with DAC curve construction
  • Detection and accurate sizing of root cracks & porosity
  • Preparation of formal NDT inspection test reports
  • Zero tolerance for missed rejectable structural cracks

Book NDT Examination

Examinations held in climate-controlled diagnostic laboratory.

Calculate Fee
ServicesFee QuoteWhatsAppCall